When I purchased this little charger back in 1970 I didn't think I'd be writing about it today but here we are! Back then I was a lot younger, I had an old car for transportation, and it had an old battery. It didn't have a lot of cranking power when the weather turned cold, so I had to find a way to keep my wheels running. This little charger was the answer to my problems. But I digress.


[ photo close up of front panel ]


What brings us here today is a friend of mine, asking how to build a battery charger. He tells me that he has a couple of transformers and wonders what else is needed to make one. Well that's a pretty good starting point having a transformer, and there's not much more required to complete the job. A charger for a car battery can be really very simple, as long as there is a human to monitor the charging process. Cars and tractors have a Lead Acid wet cell battery, usually 6 or 12 volts.

We'll be looking at this Woodward-Schumacher Electric Corp. One Amp battery charger to get some ideas about what it takes to make one. I did a Google search and found Woodward-Schumacher is still in business designing and selling battery chargers. That is remarkable.

Battery Charging Basics

To charge a Lead Acid battery is a fairly easy. DC current is driven into the battery from a controlled power source. Controlled to limit the current to a maximum level appropriate for the size of the battery, usually around 10% of the battery capacity. A 100 Amp Hour battery would be 10 Amps maximum, but following the battery manufacturer's recommendation is always the best option. This One Amp charger can charge a larger capacity battery, it will just take longer to get fully charged.



In the case of this One Amp charger the control is not very sophisticated or complex:
  1. It supplies limited power to the battery, 1 amp DC, due to the size of the transformer.
  2. The voltage output is limited by the transformer to about 15 volts.
The simplicity of this charger is elegant because of these two parameters, however care must be taken by the  person using a unit like this because the uncontrolled parameter is time. Leave the charger connected for too long and the electrolyte will start to boil away, which is a bad thing of course. Electrolyte boiling begins around 14.5 volts for a 12 volt wet cell battery.

Voltage of lead acid battery type for a car, engine cranking (intermittent high current demand).
  • Dead 12.0 volts
  • Operating 13.5 volts
  • Charging 14.8 to 15.1 volts
Deep cycle lead acid Absorbed Glass Matt (AGM) type RV or solar home battery (steady low current demand). Notice the charging voltage never gets to the boiling point. That's by design to prevent electrolyte loss which is unrecoverable with a sealed battery.
  • Dead 12.0 volts
  • Operating 12.7 volts
  • Charging 14.4 volts
These are very general voltages because we've completely ignored temperature which will change these significantly. Cold temperatures make these voltage points higher while warm temperatures make them lower by a few tenths of a volt.

Let's get on with the details of building a charger like this one using one of his transformers.

The Circuit

Here is a schematic diagram of what is inside the One Amp charger. The first thing that happens is the AC mains connect to a transformer which does three things:
  1. Isolate the rest of the circuit from the power grid for your safety.
  2. Reduce the voltage to the level useful to the battery.
  3. Limit the amount of current going into the battery.
That third item is accomplished partially by #2, and the rest is a result of the AC impedance of the transformer itself. An iron core transformer like this one can be built with an air gap, air spaces, between the lamination's on the inside where you can't see them. Air spaces tend to reduce coupling between primary and secondary winding therefore limiting the power available at the secondary where the battery will attach.

The circuit also has a switch for selecting the correct voltage for the battery to be charged. AC voltage on the secondary of the transformer needs to be changed into DC (Direct Current) appropriate for charging a battery which is naturally DC itself. That job is performed by the Diode, only allowing current to pass through it in one direction. The direction of the arrow points to the Plus (+) side of the battery. Next there is a Thermal Breaker. This is a temperature controlled circuit breaker which will open and stop current flow to the battery if the current is too high. It is a safety device for protecting the battery and the charger from damage. After a short time period a Thermal Breaker will close the circuit and start current flowing into the battery again.

[ schematic diagram ]

Transformer


Checking the secondary AC voltage on the One Amp charger will show us about what we need to build our charger. Here's what I get with my Fluke 77 meter.


[ photo of DMM reading 15.81v ]

The meter is reading 15.81 volts AC. I think the Fluke 77 actually reads AVERAGE voltage, not RMS. RMS readings are more accurate for measuring sine wave voltages, but this is close enough for us. The voltage shown here is reduced further by the drop across the rectifier changing the AC voltage to DC voltage for the battery.

Rectifier

The One Amp charger uses an older style rectifier called a selenium rectifier. It may be old technology but they are still used in new equipment today. These are interesting devices and have some unique characteristics which make them particularly desirable for use in a battery charger. A Google search turned up an interesting article written by Rich Bonkowski describing the selenium rectifier in easy to understand terms. Here is what the selenium rectifier looks like in the One Amp charger. It's about 1 1/2 inch square.


[ photo of selenium rectifier ]

We subtract the voltage drop across the rectifier from the AC voltage reading on the secondary of the transformer which brings us closer to the voltage rating of the battery. Keep in mind the voltage output of the charger needs to be higher than the battery terminal voltage or there won't be current flow into the battery.

Here's what I measured for voltage drop across the selenium rectifier. Voltage vertical axis, current horizontal axis. Looks like the operating region will be around 1.50 volts drop from the selenium rectifier.


[ chart selenium rectifier voltage drop vs current ]

I connected a fairly dead battery to the One Amp charger and read about 0.8 Amps on the meter resulting in about 1.5 volts being dropped across the rectifier.

I even made an attempt to take a picture of the waveform on the oscilloscope. I say attempt because it is an older analog Tektronix Scope with no photo capabilities at all. Here is what my old Sony camera did with it.


[ photo of selenium rectifier AC waveform ]

It's hard to see any graticule markings in the picture, but the scale is 5 volts per div (vertical) and 5mS per div (horizontal), sync is set to the line frequency. It shows about 17.5 volts peak and this is with a 0.8 amp load. What this tells us is the battery voltage would have to rise to 17.5 volts for the current to drop to zero. Ouch!

This is why the charger MUST be monitored by a human during use!

For the voltage to go that high would require extraordinary circumstances.

Using Modern Parts

Rectifier

If you will be using a silicon diode rectifier in place of a selenium device there will be less voltage drop which means higher voltage to the battery. A silicon diode rectifier has a lower impedance than selenium resulting in higher current into the battery. Silicon diodes do not have the 'self healing' ability that selenium does which means if you connect to a very dead battery you might end up frying the silicon rectifier. Hence the need to have a fuse or some kind of safety limiting device to prevent this from happening.

Transformer

Modern transformers are OK to use, but a general purpose transformer may have a low impedance resulting in higher a current to the battery than your design. There are transformers designed for battery charger service which have built-in current limiting because of the air gaps within the iron core lamination. A low value high power resistor would remedy this, and also soften the surge capability of the silicon diode, however it will introduce a source of power loss and will generate heat. This is usually an equitable trade off in the design when the transformer isn't a perfect match.

The Meter

The meter seen on the top of the One Amp charger is a modification I added to it myself not long after I purchased it. It's a standard 0-1 ma DC meter. I made a shunt out of a small coil of copper magnet wire so it would read 1 amp full scale. The shunt passes most of the current, leaving a small amount for the meter.


[ photo of meter from rear ]


[ photo close up of meter shunt wire winding ]

In the close up photo you can see the loop of wire above the coil. That is the half way point in the coil. Half of the coil is wound in one direction and the other half is wound in the opposite direction. The purpose of this is to make the coil nonmagnetic when current is passing through it. If the coil were wound in one direction only you would end up with an electromagnet which may affect the reading displayed on the meter. In any case, I have found the addition of the meter to be useful in helping determine if a battery is really dead or just needing to be topped off.

Using the One Amp Charger

I attached the One Amp charger to a battery in my workshop and took some pictures of it in operation. The battery shown here is part of a bank of 12 volt AGM deep cycle batteries that I use for lights and other things. They are not automotive cranking type batteries but will serve as a load for this demonstration. You can see the battery clips attached to the top of this 33 amp hour battery.


[ photo of battery being charged with the One Amp Charger ]



[ photos showing charge current DC, battery voltage DC, transformer voltage AC, low battery ]


The readings here show the battery charge state is a little low at 12.61 volts, therefore is taking a little power from the charger. Charging current is 0.9 amps. Fluke meter shows AC volts from the transformer at  about 14.01 volts, a little less than we saw above (15.81 volts) with no battery connected. This is because the battery is accepting current during the charge which loads down the transformer output voltage. All of these readings look normal and acceptable.


As the battery charges it's terminal voltage goes up and the readings look a little different. Charge current decreases, transformer AC voltage output increases. The battery is clearly accepting the charge and on its way to being restored to full capacity.



[ photos showing charge current DC, battery voltage DC, transformer voltage AC, high battery ]

Well that about raps it up. This little One Amp charger has served me well over the years. As we've seen it is a pretty simple circuit to build. The use of modern general purpose components need to be considered when building a charger like this one. Good luck with your design.